MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 1.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.015 INCHES NOMINAL |
AKDX | WINDING QUANTITY | 2 |
APNA | WINDING DC RESISTANCE RATING | 450.0 OHMS NOMINAL ALL WINDINGS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 16 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 12.0 AMPERES DC RESISTIVE LOAD |
FEAT | SPECIAL FEATURES | PLUG IN TERMINALS ARE 0.175 IN. LONG. |
TTQY | TERMINAL TYPE AND QUANTITY | 16 PIN ALL FUNCTIONS |
ABKW | OVERALL HEIGHT | 1.015 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | CASS STATION, GENERAL ELECTRIC |
APCN | COIL QUANTITY | 2 |
APNP | DUTY TYPE | CONTINUOUS |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
TEST | TEST DATA DOCUMENT | 30003-2037AS196 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR |