You have arrived on the Request for Quote (RFQ) page for part number 41389, a Freed Transformer Company component that is listed with the product description “Reactor” and NSN 5950-00-004-2071 for fast identification. By using the form supplied below, you can offer details regarding your requirements to secure customized procurement solutions for your consideration. As our goal is to provide quick service, you can expect a response within 15 minutes of our staff members reviewing your submission. Alternatively, if you use the email or phone number at the bottom of the webpage, you can directly connect with our experts to discuss your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside Freed Transformer Company part number 41389, you can seamlessly search for more items from this manufacturer or CAGECode 73386 using our curated catalogs. Similarly, we also offer means for locating other products that belong to FSC 5950 Coils and Transformers, which this component falls under having the NSN 5950-00-004-2071. Whether you desire part number 41389 or other NSN components, you can rest assured that our entire inventory is sourced from reputable manufacturers and suppliers. Bearing this in mind, kick off procurement today to see why so many customers select Aero Defence Solutions as their trusted purchasing hub.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-004-2071 Item PartTypeName: REACTOR | 5950 | 000042071 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
41389 | 6 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND VIBRATION RESISTANT AND FLAME RESISTANT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.140 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.090 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.110 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.146 INCHES MINIMUM SINGLE GROUP AND 0.166 INCHES MAXIMUM SINGLE GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
ACYV | INDUCTANCE RATING | 9.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.450 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.780 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.500 SINGLE COMPONENT SINGLE WINDING |
TEST | TEST DATA DOCUMENT | 82577-986056 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS,INDIVIDUAL MANUFACTUREER STANDARDS,ETC.). |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote