You have arrived on the Request for Quote (RFQ) page for part number G-3939, a L 3 Communications Corporation component that is listed with the product description “Circuitbreaker” and NSN 5925-01-495-2554 for fast identification. By using the form supplied below, you can offer details regarding your requirements to secure customized procurement solutions for your consideration. As our goal is to provide quick service, you can expect a response within 15 minutes of our staff members reviewing your submission. Alternatively, if you use the email or phone number at the bottom of the webpage, you can directly connect with our experts to discuss your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside L 3 Communications Corporation part number G-3939, you can seamlessly search for more items from this manufacturer or CAGECode 28199 using our curated catalogs. Similarly, we also offer means for locating other products that belong to FSC 5925 Circuit Breakers, which this component falls under having the NSN 5925-01-495-2554. Whether you desire part number G-3939 or other NSN components, you can rest assured that our entire inventory is sourced from reputable manufacturers and suppliers. Bearing this in mind, kick off procurement today to see why so many customers select Aero Defence Solutions as their trusted purchasing hub.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-495-2554 Item Description: Circuitbreaker | 5925 | 014952554 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
G-3939 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | AT POLE ONE |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
CQJX | Nominal Thread Size | 0.375 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 1.640 INCHES MAXIMUM |
ABMK | Overall Width | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
THSD | Thread Series Designator | UNEF |
ADAQ | Body Length | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
TTQY | Terminal Type And Quantity | 4 QUICK DISCONNECT, MALE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.499 INCHES MINIMUM AND 1.561 INCHES MAXIMUM |
ABXD | Bushing Length | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
CMLP | Thread Quantity Per Inch | 32 |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAT | Body Width | 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.035 MINIMUM AT 200 PCT ALL LOCATIONS AND 7.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF |