You have arrived on the Request for Quote (RFQ) page for part number 30-3002-1, a Libby Power Systems Llc component that is listed with the product description “Circuitbreaker” and NSN 5925-00-135-4197 for fast identification. By using the form supplied below, you can offer details regarding your requirements to secure customized procurement solutions for your consideration. As our goal is to provide quick service, you can expect a response within 15 minutes of our staff members reviewing your submission. Alternatively, if you use the email or phone number at the bottom of the webpage, you can directly connect with our experts to discuss your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside Libby Power Systems Llc part number 30-3002-1, you can seamlessly search for more items from this manufacturer or CAGECode 36024 using our curated catalogs. Similarly, we also offer means for locating other products that belong to FSC 5925 Circuit Breakers, which this component falls under having the NSN 5925-00-135-4197. Whether you desire part number 30-3002-1 or other NSN components, you can rest assured that our entire inventory is sourced from reputable manufacturers and suppliers. Bearing this in mind, kick off procurement today to see why so many customers select Aero Defence Solutions as their trusted purchasing hub.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-135-4197 Item PartTypeName: CIRCUIT BREAKER | 5925 | 001354197 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
30-3002-1 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
ABHP | OVERALL LENGTH | 10.125 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.812 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.500 INCHES NOMINAL |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,SINGLE THROW,NORMALLY OPEN |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 3 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 208.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 25000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS AND TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE,TWO,AND THREE LINKED |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 CONTROL |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 9.000 MINIMUM AT 130 PCT AND 120.000 MAXIMUM AT 130 PCT AND 60.000 MINIMUM AT 150 PCT AND 250.000 MAXIMUM AT 150 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 77.0 DEG FAHRENHEIT NOMINAL ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | WIRE LEAD |
CWJK | CASE MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | UNDERV0LTAGE PROTECTION DEVICE WITH 60 INCH LEADS INCLUDED |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB,SOLDER LUG |