You have arrived on the Request for Quote (RFQ) page for part number DA-7035-153-9N, a Mercoid Corp component that is listed with the product description “Switch Thermostatic” and NSN 5930-01-566-2942 for fast identification. By using the form supplied below, you can offer details regarding your requirements to secure customized procurement solutions for your consideration. As our goal is to provide quick service, you can expect a response within 15 minutes of our staff members reviewing your submission. Alternatively, if you use the email or phone number at the bottom of the webpage, you can directly connect with our experts to discuss your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside Mercoid Corp part number DA-7035-153-9N, you can seamlessly search for more items from this manufacturer or CAGECode 39709 using our curated catalogs. Similarly, we also offer means for locating other products that belong to FSC 5930 Switches, which this component falls under having the NSN 5930-01-566-2942. Whether you desire part number DA-7035-153-9N or other NSN components, you can rest assured that our entire inventory is sourced from reputable manufacturers and suppliers. Bearing this in mind, kick off procurement today to see why so many customers select Aero Defence Solutions as their trusted purchasing hub.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-566-2942 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 015662942 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
DA-7035-153-R9 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQGB | Contact Action Stimulus | INCREASE |
CTHF | Contact Load Current Rating | 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | Contact Adjustability | ACTUATION POINT ADJUSTABLE |
CTYM | Contact Adjustment Range | +175.00/+290.00 ACTUATION POINT DEGREES CELSIUS AND +350.00/+550.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTZB | Contact Voltage Rating In Volts | 240.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTYS | Contact Adjustment Type | EXTERNAL ACTUATION POINT KNOB |
CTZB | Contact Voltage Rating In Volts | 240.0 DC AT SEA LEVEL FIFTH VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 120.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 480.0 AC AT SEA LEVEL THIRD VOLTAGE |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, DOUBLE BREAK/DOUBLE MAKE, PERMANENT JUMPER, BOTH POSITIONS MAINTAINED |
CXCY | Part Name Assigned By Controlling Agency | TEMPERATURE SWITCH |
ABHP | Overall Length | 7.015 INCHES NOMINAL |
CTZB | Contact Voltage Rating In Volts | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
MEDA | Media For Which Designed | GAS OR LIQUID |
AGAV | End Item Identification | KNOLLS ATOMIC POWER LAB-SPECIAL PROJECT MANAGEMENT SYSTEM |
AKBY | Temp Sensing Element Type | BOURDON TUBE OR CAPILLARY TUBE |
ABKW | Overall Height | 2.250 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
CTHF | Contact Load Current Rating | 15.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | Contact Load Current Rating | 0.2 AMPERES RESISTIVE LOAD FIFTH VOLTAGE |
CTHF | Contact Load Current Rating | 0.5 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CSCF | Terminal Type | SCREW |
CTHF | Contact Load Current Rating | 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
AEVT | Capillary Tube Length | 72.0 INCHES MAXIMUM |
STYL | Style Designator | CYLINDRICAL W/PORT |
AXGY | Mounting Method | BRACKET |
ABPM | Body Diameter | 6.015 INCHES NOMINAL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.