You have arrived on the Request for Quote (RFQ) page for part number 583-G111-J3M1-C4S1U-5A, a Oakland Industries Ltd component that is listed with the product description “Circuitbreaker” and NSN 5925-01-582-4346 for fast identification. By using the form supplied below, you can offer details regarding your requirements to secure customized procurement solutions for your consideration. As our goal is to provide quick service, you can expect a response within 15 minutes of our staff members reviewing your submission. Alternatively, if you use the email or phone number at the bottom of the webpage, you can directly connect with our experts to discuss your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside Oakland Industries Ltd part number 583-G111-J3M1-C4S1U-5A, you can seamlessly search for more items from this manufacturer or CAGECode 06402 using our curated catalogs. Similarly, we also offer means for locating other products that belong to FSC 5925 Circuit Breakers, which this component falls under having the NSN 5925-01-582-4346. Whether you desire part number 583-G111-J3M1-C4S1U-5A or other NSN components, you can rest assured that our entire inventory is sourced from reputable manufacturers and suppliers. Bearing this in mind, kick off procurement today to see why so many customers select Aero Defence Solutions as their trusted purchasing hub.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-582-4346 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015824346 | P | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
583-G111-J3M1-C4S1U-5A | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 6 SCREW |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC ALL LOCATIONS AND 5.0 AMPERES DC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 200.0 AC ALL LOCATIONS AND 28.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2500.0 AC ALL LOCATIONS AND 6000.0 DC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CXCY | Part Name Assigned By Controlling Agency | HIGH PERFORMANCE THERMAL CIRCUIT BREAKER |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | -55.0 DEG CELSIUS MINIMUM ALL LOCATIONS AND 90.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
THSD | Thread Series Designator | UNC |
CMLP | Thread Quantity Per Inch | 32 |
SUPP | Supplementary Features | ITEM HAS AUXILIARY CONTACT (N/C) (CONNECTOR TO EN 3155-016M2018, SIZE 20); BARRIER INCLUDED (19.5 WIDE AND 37.7 LONG-BOTH MM; VOLT DROP PER POLE 260MV |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AKPX | Pole Quantity | 3 |
CPRJ | Trip Release Method | THERMAL ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
CQJX | Nominal Thread Size | 6.0 MILLIMETERS |