You have arrived on the Request for Quote (RFQ) page for part number AP16-2R-7331-1, a Sensata Technologies Inc component that is listed with the product description “Circuit Breaker” and NSN 5925-01-158-4168 for fast identification. By using the form supplied below, you can offer details regarding your requirements to secure customized procurement solutions for your consideration. As our goal is to provide quick service, you can expect a response within 15 minutes of our staff members reviewing your submission. Alternatively, if you use the email or phone number at the bottom of the webpage, you can directly connect with our experts to discuss your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside Sensata Technologies Inc part number AP16-2R-7331-1, you can seamlessly search for more items from this manufacturer or CAGECode 81541 using our curated catalogs. Similarly, we also offer means for locating other products that belong to FSC 5925 Circuit Breakers, which this component falls under having the NSN 5925-01-158-4168. Whether you desire part number AP16-2R-7331-1 or other NSN components, you can rest assured that our entire inventory is sourced from reputable manufacturers and suppliers. Bearing this in mind, kick off procurement today to see why so many customers select Aero Defence Solutions as their trusted purchasing hub.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-158-4168 Item Description: CIRCUIT BREAKER | 5925 | 011584168 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP16-2R-7331-1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | POLE QUANTITY | 2 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 0.6 AMPERES AC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 4.000 MINIMUM SECOND LOCATION AND 40.000 MAXIMUM SECOND LOCATION |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 6.000 MINIMUM FIRST LOCATION AND 50.000 MAXIMUM FIRST LOCATION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.000 MINIMUM AT 125 PCT SECOND LOCATION AND 40.000 MAXIMUM AT 125 PCT SECOND LOCATION AND 0.850 MINIMUM AT 200 PCT SECOND LOCATION AND 4.000 MAXIMUM AT 200 PCT SECOND LOCATION AND 0.001 MINIMUM AT 400 PCT SECOND LOCATION AND 0.500 MAXIMUM |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.000 MINIMUM AT 125 PCT FIRST LOCATION AND 50.000 MAXIMUM AT 125 PCT FIRST LOCATION AND 0.900 MINIMUM AT 200 PCT FIRST LOCATION AND 4.000 MAXIMUM AT 200 PCT FIRST LOCATION AND 0.010 MINIMUM AT 400 PCT FIRST LOCATION AND 0.090 MAXIMUM AT 40 |
FREQ | FREQUENCY IN HERTZ | 400.0 FIRST LOCATION |