You have arrived on the Request for Quote (RFQ) page for part number J72-0073, a Ward Leonard Electric Company Inc component that is listed with the product description “Transformer Power” and NSN 5950-00-985-1668 for fast identification. By using the form supplied below, you can offer details regarding your requirements to secure customized procurement solutions for your consideration. As our goal is to provide quick service, you can expect a response within 15 minutes of our staff members reviewing your submission. Alternatively, if you use the email or phone number at the bottom of the webpage, you can directly connect with our experts to discuss your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside Ward Leonard Electric Company Inc part number J72-0073, you can seamlessly search for more items from this manufacturer or CAGECode 20019 using our curated catalogs. Similarly, we also offer means for locating other products that belong to FSC 5950 Coils and Transformers, which this component falls under having the NSN 5950-00-985-1668. Whether you desire part number J72-0073 or other NSN components, you can rest assured that our entire inventory is sourced from reputable manufacturers and suppliers. Bearing this in mind, kick off procurement today to see why so many customers select Aero Defence Solutions as their trusted purchasing hub.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-985-1668 Item PartTypeName: TRANSFORMER,POWER | 5950 | 009851668 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
F90-X | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.750 INCHES MINIMUM AND 2.870 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.620 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.620 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | OPEN |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 40.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD |